Orifice plates
Prix et délai sur devis



Cliquez pour agrandirCaractéristiques
| Particularité | Spécifications |
|---|---|
| Particularité | Design |
| Particularité | Conforms to ISA RP 3.2 , DIN 1952 , BS 1042, ISO-5167 |
| Particularité | Types |
| Particularité | Square edge concentric, Quadrant edged, Conical entrance, Eccentric, Segmental |
| Particularité | Plate material |
| Particularité | SS304 , SS316 , SS316L as standard. Hastelloy-C , Monel , PP , PVC , PTFE coated , etc. can be given on request. |
| Particularité | Orifice Bore |
| Particularité | In accordance with ISO-5167, BS-1042, ASME MFC 3M, R.W.Miller, L.K.Spink, AGA-3 |
| Particularité | Tab Plate |
| Particularité | In the same material as plate & is welded to orifice plate. Tab plate integral to the Orifice plate (i.e. without welding) can also be offered as a special case. Vent / Drain |
| Particularité | Vent or Drain holes are provided as per customer's requirement. The diameter of the vent or drain holes are as per ISA RP 3.2 Flange UnionWeld neck, Slip on, Threaded, Socket welded with RF or RTJ facing Orifice flanges are in accordance with ANSI B16.36 with minimum flange rating of 300 for sizes up to 8" or male - female flanges in accordance with ANSI B16.5 Pressure Tappings |
| Particularité | Corner tappings are recommended for sizes upto 1 ½"; Flange taps from 2" to 16" ; D - D/2 taps for higher sizes GasketCAF as per IS: 2712 Gr 0/1 , SS spiral wound + CAF , SS spiral wound + Grafoil, SS spiral wound + PTFE are normally supplied as per process requirement. Other materials available on request. For RTJ flanges , the plate is fixed on the plate holder. The plate holder is in Soft Iron material & acts as a gasket. Studs / NutsASTM A193 Gr.B7/A-194 Gr.2H as standard, Other material on request. |
| Particularité | Jack ScrewASTM A193 Gr.B7/A-194 Gr.2H as standard, Other material on request. |
Description
Concentric Square Edge
The concentric orifice plate with square vice edge is commonly used for flow measurement. It has special features, simple structures and high accuracy. It is very easy to install and replace. The orifice plates are properly finished to the dimensions according to the applicable standard (surface roughness, flatness). These plates are recommended for the measurement of clean liquid, gas and steam flows, for Reynolds numbers ranging from 10 000 to 10 000 000.
Eccentric
Used for liquids containing solid particles that are likely to produce sediment or water vapour that may contain condensate, this diaphragm is used with the orifice eccentrically downwards to avoid sediment. Similarly, for gases or vapours, the diaphragm can be installed with the orifice eccentric to the pipe bore to avoid the presence of gas or vapour in the vicinity.
Segmental
Segmental orifice plates are used where there are large quantities of entrained water or air or particles suspended in the fluid. This prevents build-up at the front of the plate. The eccentric orifice is placed at the bottom for gases and at the top for liquids.
Profiled edges
The inlet edge of the bore of this orifice plate is rounded in a quarter circle. This diaphragm is generally used for viscous fluids and for Reynolds numbers between 2000 and 10000.
Conical inlet
These conical inlet orifice plates are used for low Reynolds numbers between 80 and 2000. It provides more constant or predictable discharge coefficients. At lower Reynolds numbers, the discharge coefficient of square sharp edge concentric orifice plates can vary by up to 30%. They are intended for use with viscous fluids.